SUP 10/23
Publication date: 29 JUN 23
Effective from: 28 AUG 23
Effective to: 08 SEP 23
Part of VFR manual affected by this VFR-SUP: VFR-ENR-1
The following VFR-SUP have been incorporated in this VFR-SUP and therfore cancelled:
SUP: 9
The following NOTAMs are incorporated in this VFR-SUP and will be cancelled by NOTAM:
NOTAM: NIL
Temporary Reserved Areas (TRA) for international military air exercise ODON 2023

From 28 AUG 2023 to 01 SEP 2023 and from 04 SEP 2023 to 08 SEP 2023 the areas for international military air exercise ODON 2023 in bellow mentioned scale are temporary reserved:

1Time period of areas:

Date Time (UTC) Areas Remark
28 AUG - 01 SEP 2023
(Monday - Friday)
and
04 - 08 SEP 2023
(Monday - Friday)
0800 - 1000
or
1230 - 1500
ODON 11, ODON 12, ODON 13, ODON 21, ODON 22, ODON 31, ODON 32, ODON 33 The areas have a TRA character.
For the possible entry of other users of the airspace of the Czech Republic, not participating in this exercise, the following applies in the ODON areas:
• airspace class "G" -
from GND to 1000 ft AGL,
• airspace class “E” -
from 1000 ft AGL to FL095.
The areas ODON 11, ODON 12 and ODON 13 will not be activated together with the areas ODON 31, ODON 32 and ODON 33.
Each of the areas will be activated for a maximum of 2.5 hours per day.

2Horizontal and vertical limits of the areas:

Area name Vertical limits Horizontal limits Note
ODON 11 1000 ft AGL
GND
49 41 56,71 N 014 13 39,73 E -
49 38 28,05 N 014 18 03,71 E -
49 19 56,98 N 013 53 56,70 E -
49 27 52,64 N 013 40 59,14 E -
49 41 56,71 N 014 13 39,73 E
Horizontal limit of the ODON 11 is identical with horizontal limits of LKTRA76.
ODON 11 will always be activated simultaneously with LKTRA76.
ODON 12 1000 ft AGL
GND
49 38 28,05 N 014 18 03,71 E -
49 23 41,08 N 014 36 42,60 E -
49 13 39,32 N 014 21 28,83 E -
49 07 31,77 N 014 12 08,96 E -
49 19 56,98 N 013 53 56,70 E -
49 38 28,05 N 014 18 03,71 E
Horizontal limit of the ODON 12 is identical with horizontal limits of LKTRA77.
ODON 12 will always be activated simultaneously with LKTRA77.
ODON 13 FL075
GND
49 23 41,08 N 014 36 42,60 E -
49 09 57,74 N 014 53 46,79 E -
49 03 06,72 N 014 50 24,82 E -
49 03 06,37 N 014 45 14,26 E -
49 05 20,21 N 014 30 37,38 E -
49 05 47,65 N 014 26 48,41 E -
49 07 31,77 N 014 12 08,96 E -
49 23 41,08 N 014 36 42,60 E
Horizontal limit of the ODON 13 is identical with horizontal limits of LKTRA78.
LKTRA78 can be activated to the ODON 13 area.
In justified cases, the activity in the ATZ LKSO can also be carried out when ODON 13 is activated, and this on the basis of proper coordination with the CRC unit.
ODON 21 3500 ft AMSL
GND
49 57 33,00 N 015 11 56,98 E -
49 56 05,78 N 015 12 04,68 E -
49 53 54,69 N 015 15 11,69 E -
49 50 35,84 N 015 07 57,97 E -
49 37 13,04 N 015 03 20,82 E -
49 30 46,42 N 014 41 34,91 E -
49 27 49,36 N 014 24 03,35 E -
49 30 41,94 N 014 25 09,71 E -
49 33 26,68 N 014 40 06,09 E -
49 40 04,02 N 014 58 39,06 E -
49 52 39,84 N 015 03 19,90 E -
49 57 33,00 N 015 11 56,98 E
Horizontal limit of the ODON 21 is identical with horizontal limits of LKTSA26.
LKTSA26 will not be activated at the same time as the ODON 21 area.
ODON 22 FL095
3500 ft AMSL
49 50 17,74 N 015 37 23,64 E -
49 45 21,43 N 015 38 53,98 E -
49 39 54,56 N 015 33 47,36 E -
49 37 26,38 N 015 27 39,64 E -
49 31 03,99 N 015 27 12,46 E -
49 21 58,21 N 015 16 35,64 E -
49 14 10,97 N 014 55 19,35 E -
49 09 57,74 N 014 53 46,79 E -
49 06 41,22 N 014 52 10,06 E -
49 06 58,50 N 014 46 36,58 E -
49 15 51,03 N 014 49 48,92 E -
49 24 45,44 N 015 14 27,75 E -
49 32 15,15 N 015 22 13,16 E -
49 39 33,98 N 015 22 44,00 E -
49 43 14,36 N 015 31 15,61 E -
49 46 38,74 N 015 31 13,60 E -
49 50 17,74 N 015 37 23,64 E
Horizontal limit of the ODON 22 is identical with horizontal limits of LKTSA27.
LKTSA27 will not be activated at the same time as the ODON 22 area.
ODON 31 1000 ft AGL
GND
49 50 17,74 N 015 37 23,64 E -
49 46 09,37 N 015 50 58,58 E -
49 33 35,75 N 016 13 18,88 E -
49 30 44,56 N 016 06 40,45 E -
49 44 42,77 N 015 42 17,67 E -
49 46 38,74 N 015 31 13,60 E -
49 50 17,74 N 015 37 23,64 E
Horizontal limit of the ODON 31 is identical with horizontal limits of LKTSA20.
LKTSA20 will not be activated at the same time as the ODON 31 area.
LKTRA31 can be activated to the ODON 31 area.
ODON 32 5000 ft AMSL
GND
49 42 55,11 N 016 35 12,61 E -
49 27 32,96 N 016 42 48,91 E -
49 25 30,09 N 016 33 03,64 E -
49 30 44,56 N 016 06 40,45 E -
49 33 35,75 N 016 13 18,88 E -
49 37 37,38 N 016 22 44,16 E -
49 42 55,11 N 016 35 12,61 E
Horizontal limit of the ODON 32 is identical with horizontal limits of LKTRA33.
LKTRA33 can be activated to the ODON 32 area.
ODON 33 FL095
GND
49 27 32,96 N 016 42 48,91 E -
49 42 55,11 N 016 35 12,61 E -
49 45 16,63 N 016 40 47,88 E -
49 46 35,89 N 017 32 27,73 E -
49 44 31,88 N 017 26 35,72 E -
49 35 58,88 N 017 23 50,72 E -
49 27 32,96 N 016 42 48,91 E
Horizontal limit of the ODON 33 is partially identical with horizontal limits of LKTRA34.
In justified cases, the activity in the ATZ LKOL can also be carried out when ODON 33 is activated, and this on the basis of proper coordination with the CRC unit.

3Rules for using the areas for ODON 2023:

3.1These areas have the character of TRA.

3.2These areas take priority over affected TRA/TSA areas published in AIP CR (ENR 5.2 and AIP SUP) and also over areas promulgated via NOTAM.

3.3These areas are used in whole range of given vertical and horizontal limits unless otherwise stated in this SUP.

3.4Planned usage of these areas, including subsequent changes (abatement or cancellation of the restriction) will be promulgated by AUP/UUP.

3.5Each area will be activated and deactivated according to procedures published in the AIP CR.

3.6Existing areas published in AIP CR, ENR 5.2 will be used within the air exercise.

4Rules for entering of other users of the CR airspace not participating in the exercise ODON 2023 to these areas:

4.1For the possible entry (overflight) of other users of the Czech Republic airspace not participating in this exercise, the following airspace classes are applied in these areas:

Note: These airspace classes do not apply to OAT flights conducted as part of this exercise.

4.2Information about current activation status of the areas will be provided by FIC Praha and ACC Praha. Validity of submitted information is 15 minutes. After this period pilot shall consider the areas activated.

4.3Flights of aircraft not participating in this exercise through these areas will not be cleared with the following exceptions:

5Contacts: